Daikin
FTX / FTK AXVJU
3P601789-1 A · operation
Choose this family →STEP 2 · BRAND AND FAMILY
Wall-mounted indoor unit and outdoor unit. Select a documented family to study or look up a problem.
1 family
Daikin
3P601789-1 A · operation
Choose this family →No matches in the documented families. See “I cannot find my brand or model.”
THEORY → DIAGRAM → VIRTUAL PRACTICE
Vapor-compression cycle in cooling mode. Pressure, phase and heat transfer are different concepts.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Receives low-pressure vapor and discharges it at high pressure; requires work.
Does the entire low-pressure path contain only vapor?
No: there is a liquid/vapor mixture after expansion. Low pressure does not imply a single phase.
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
This library does not yet cover every unit. If the model does not match, do not use another guide as a diagnosis. Check the visible nameplate and your equipment's manual without opening electrical compartments.
You can share a nameplate photo or manual link with AC Doctor Cool to request a review.
Ask about my model on WhatsApp ↗