LESSON 15.1
Furnaces and boilers
A furnace heats air; a boiler transfers heat to water or produces steam, depending on its design. The source may be fuel or electricity. Distribution, safety devices and maintenance vary by application.
Combustion introduces risks involving fuel, flue-gas venting and carbon monoxide. Adjusting valves or bypassing protections is not beginner practice. A suspected gas leak or CO alarm requires leaving the area and contacting the appropriate emergency services.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Cooling and heating: roles change
Compare exchanger roles. The reversing valve changes connections; the compressor does not pump backward.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
In cooling it absorbs heat from the space; in heating it delivers heat to the space.
Heat exchange changes; valve piping is not shown.
Think before continuing
Does switching to heating reverse compressor pumping direction?
Show explanation
No. Connections and exchanger roles change; suction and discharge retain their functions.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Are smell or flame appearance enough to verify safe combustion?
View the explained answer
No. It requires evaluation, instruments and procedures performed by qualified personnel; carbon monoxide cannot be detected by smell.
LESSON 15.2
DOAS, ERV and HRV
A dedicated outdoor air system, DOAS, addresses ventilation separately from zone conditioning. An HRV exchanges heat; an ERV can also exchange moisture, depending on its construction.
Recovering energy does not mean eliminating the entire ventilation load. The design must address climate, airflow rates, condensation, filtration and proper separation of air streams. Study the air path before interpreting a marketing label.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Return air, supply air and ventilation
Functional air path. Actual fan, filter and coil positions depend on the design.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Brings room air back for conditioning. Recirculation does not guarantee outdoor air intake.
Recirculation only in this example.
Think before continuing
If the fan runs, do we know that fresh air is entering?
Show explanation
No. Toggle the drawing’s outdoor inlet: recirculation can operate without outdoor ventilation.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Does an ERV, by itself, guarantee the desired humidity throughout the building?
View the explained answer
No. Its effect depends on the design and conditions; the total load may require additional treatment.
LESSON 15.3
Filters, UV and source control
Air quality is addressed through source control, appropriate ventilation and supplemental filtration or air cleaning. A particle filter does not necessarily remove gases. Selection must respect the system's airflow and capacity.
UV devices need appropriate design, placement and protection. They do not replace cleaning or solve every cause of contamination. Installing an accessory is not a promise to sterilize a home or prevent disease.
THEORY → DIAGRAM → VIRTUAL PRACTICE
Return air, supply air and ventilation
Functional air path. Actual fan, filter and coil positions depend on the design.
Functional diagramOn small screens, scroll the drawing horizontally. Every component is also available as a button.
Solid line: indicated path. Arrow: direction. Dashed line: signal or functional relationship. Labels identify every path; color is supplementary.
Select a component or follow the sequence.
Captures particles according to its rating. Filtration and ventilation serve different functions.
Recirculation only in this example.
Think before continuing
If the fan runs, do we know that fresh air is entering?
Show explanation
No. Toggle the drawing’s outdoor inlet: recirculation can operate without outdoor ventilation.
Sources and drawing scope
Original teaching drawing, not to scale. Functional blocks do not represent terminals or installation connections. Use the model-specific diagram for real work.
Check your understanding
Before selling an accessory to address an odor, what question remains unanswered?
View the explained answer
What the source is and which contaminant needs to be controlled. Without identifying the problem, a specific solution cannot be justified.
Sources for further study
- DOE · Heat pump systems ↗
- EPA · Improving indoor air quality ↗
- EPA · Air cleaners and air filters ↗
- OSHA · Control of hazardous energy ↗
Reference readings: some resources are in English. Consult the current equipment manual before any work. Access to restricted documentation is not assumed.